QV-DB swelling sealing tape

for multiple occupancy

Self-sealing, nonwoven swelling material, consisting of mechanically preprocessed, heat-fixed, fibre-bonded material, made of PP fibres and special super-waterabsorbent fibres, UV-stabilised.

Geotextile robustness class TL Geok EStB05-3-

Applications: QV-DB swelling sealing tape

Swelling material, in combination with the Swelling material, in combination with the QAK/V sealing system (WO16), is specially recommended for use in service entries for FTTH, photovoltaic, wind energy and biogas applications etc., where a grease-free seal (e.g. no dripping oil) is required.

Product advantages: QV-DB swelling sealing tape

  • Quick retrosealing
  • Grease-free seal
  • Self-sealing (up to 10 m water column) on contact with water
    - seals immediately against water, dust, smoke and noise
  • Vibration-resistant sealing
  • Resistant to notching and impact
  • No unwanted adhesion to surrounding materials
  • Can be reused several times after swelling material has thoroughly dried out
  • Lightweight.
  • Does not contain any harmful substances
Technical data:

Swelling material:
Self-sealing, nonwoven swelling material, consisting of mechanically preprocessed, heat-fixed, fibre-bonded material, made of PP fibres and special super-waterabsorbent fibres, UV-stabilised.

 

 

Universal applications:

Product features:

 Geotextile robustness class TL Geok EstB 05

 3 GRK

 Weight per unit area   dry/swollen/ dry           EN ISO 9864

 450/ 8200/ 435      g/m²

 Thickness EN ISO 10319  wet/ dry
 2 kPa
 20 kPA
 200 kPa

 2,2/ 9,5/ 4,2       mm
 1,5/ 7,0/ 1,9       mm
 0,9/ 33/ 0,92      mm

 Porosity
 Initial swelling
 Dry-wet alternation
 Frost-thaw alternation (4 cycles)


 < 5,0 x 10-9      m/s

 < 3,0 x 10-9     m/s

 < 3,9 x 10-9    m/s

 Static puncture resistance
 dry/swollen/ dry   EN ISO 12236


 1,7 / 1,0/ 1,6   mm

 Swelling pressure

 ca. 170  kN/m²

 Penetration test
 Damage (pierced hole) Ø  5 mm: unpressurised circular diffusion < 1 cm
 Water pressure increased to 7 m water column: no increase of diffusion
 Damage (pierced hole) Ø  5 mm: 7 m water column: fairly circular diffusion < 2,0 cm

 Resistance

 DIN EN Test standard

  • resistant to acids and alkaline liquids

     
  • weather-resistant

     
  • microbiologically resistant

     
  • resistance to oxidation t 110°C/ 28 days

     
  • resistance to hydrolysis 95°C

14030:2003-11

12224: 2000-11

12225:2000-12

13438:2005-02

12447:2002-03

Wolf GmbH

Zazenhäuser Straße 52
D - 70437 Stuttgart

Tel.:  +49 (0)711 87 39 41
Fax.: +49 (0)711 87 12 30

Email: Service(at)Wolf-Systems.com