For a high concentration of cables | For a low concentration of cables | ||||
Many, thin cables | Few, thicker cables | ||||
Swelling cable separator type … 2.0x .. | Swelling cable separator type … 4.2x .. | ||||
| Compartment size |
| Compartment size | ||
2,0 x 50 x 100 | < 15 mm | < 0.6 in. | 4,2 x 50 x 100 | < 25 mm | < 1.0 in. |
2,0 x 70 x 100 | 15 – 25 mm | 0.6 – 1.0 in. | 4,2 x 70 x 100 | 15 – 50 mm | 0.6 – 2.0 in. |
| Notch measurement | Packaging unit |
22.5 QV-MADS-K 2,0 x 50 x 100 | 2,0 x 50 x 100 | 5 |
22.5 QV-MADS-K 2,0 x 70 x 100 | 2,0 x 70 x 100 | 5 |
22.5 QV-MADS-K 4,2 x 50 x 100 | 4,2 x 50 x 100 | 5 |
22.5 QV-MADS-K 4,2 x 70 x 100 | 4,2 x 70 x 100 | 5 |
Gap sealing for configurations with 2-4 cables/ducts
Gap sealing for configurations with > 5-8 cables/ducts:
Case 1:
If it is possible to cover all cables/ducts with the swelling material of the QV-MADS-K swelling cable separator (1),
then the sealing for cables/ducts Nos. 5 to 8 is carried out as described in point 1.
Case 2:
If the cables/ducts could not all be completely covered by the swelling material of the QV-MADS-K cable separator (1),
then an extra piece of swelling sealing tape must be inserted between the QV-MADS-K cable separators (1, 2) or cable/duct bundles (1) and bundle (2).