2K-AM280 Levelling grout

(quick-curing)

Quick-curing, 2-component levelling grout, for repairing chipped concrete edges and/or smoothing off uneven areas.

General product information:

The quick-curing, 2-component levelling grout is used to repair chipped concrete edges and/or to smooth off uneven areas.

  • Economical, reliable repair chips in normal reinforced or non-reinforced concrete
  • For dry or damp concrete (but not in water-filled concrete components)
  • Available in easy-to-use 280 ml double-cartridge packs. Suitable for installation under
    difficult circumstances (e.g. overhead installation, installation requiring a ladder etc.)
  • Can be applied at temperatures from +5 °C to +35 °C
  • Only takes 6 minutes to apply! Cures in 45 minutes at 20 °C
  • The installation of QADK/V (valve) sealing cushions in expansion and construction
    joints in need of repair can be carried out without waiting time or in two work stages,
    once the chipped concrete has been dealt with.

Technical data:

2K-AM 280 quick-curing, 2-component, synthetic resin levelling grout

 

Composition:

2-hydroxyethyl methacrylate      2,5 - 10 %

Vinyl toluol                               2,5 - 10 %

Dibenzoyl peroxide                    < 2,5 %

 

Physical and chemical properties:

Form                                       paste

Combustion point                   > 61 °C

Vapour pressure                      ≤ 0,1 kPa (20 °C)

Density                                    1,6 - 1,8 g/ml (20 °C)

Solubility in water                  practically insoluble

Environment risk                    Water hazard class 2

 

Safety recommendations (H and P statements):

Cool, dry storage, +5 ° C to +20 ° C

H317:            Can cause allergic skin reactions

H319:            Causes serious eye irritation

H400:            Very toxic to aquatic life

H412:            Harmful to aquatic life with long-lasting effects

P273:            Avoid release to the environment

P280:            Wear protective gloves/protective clothing/eye protection/face protection.

P302+P352:  IF ON SKIN: Wash with plenty of water

P305+P351

+P338:          IF IN EYES: Wash with plenty of water for several minutes.
                      Remove contact lenses if present and easy to do.

P333+P313:  If skin irritation or a rash occurs: Get medical advice/attention.

P501:            Dispose of contents/container in accordance with the national regulation.

 

Processing time:

 Anchoring base

 [°C]

 5

 10

 20

 30

 35

 Processing time

 [min]

 20

 15

 7

 4

 2

 Curing time

 [min]

 360

 270

 180

 90

 60

Product range:

 Art.-No.

 Description

 No. of cartridges per packaging unit

 Cartridges

 

 

 30.1 2K-AM280/01

 Cartridges 280 ml

 1 pc

 30.1 2K-AM280/04

 Cartridges 280 ml

 4 pcs